Analog output module 0…20 mA / WB-MAO4-20mA

SKU code: WB-MAO4-20mA
Analog output module 0…20 mA / WB-MAO4-20mA
Analog output module 0…20 mA / WB-MAO4-20mA
Analog output module 0…20 mA / WB-MAO4-20mA
Add to favorites
Add to comparison table
Analog output module 0…20 mA / WB-MAO4-20mA
SKU code: WB-MAO4-20mA
SKU code: WB-MAO4-20mA
Stock in Germany
Pre-order only
Stock in Switzerland
Pre-order only

Features

  • Brand
    Wiren Board
All features
Price
€76.20
excluding VAT and shipping cost
Stock in Germany
Pre-order only
Stock in Switzerland
Pre-order only
Delivery
Payments
We offer three delivery options:
  • FCA – you pick up from us
  • DAP – we deliver, you do customs in your country and
  • DDP – we deliver and we do customs clearance
Wire transfers must be made net of all bank charges. Currently, w accept wired transfer only. For more payment options please contact us on sales@smartsd.ch
Order by phone+41 79 787-62-13
  • Analog Output Module with 4 Current Outputs 4-20 mA and RS-485 Interface WB-MAO4-20mA

    Analog output module with 4 current outputs 4-20 mA and RS-485 interface.

    Used to control devices with 0-20 mA, 4-20 mA interfaces - frequency converters, servo drives, air damper drives, valves, etc. in automation systems.

    Advantages

    • Galvanic isolation of outputs.
    • Flexible configuration of output control from inputs and recognition of types of pressing.
    • Diagnostics of line condition for breakage.
    • Compact housing on DIN rail.
    • Quick and easy integration into the automation and monitoring system.
    • Technical support on the portal.
    • Russian-language documentation.
    • It is possible to apply your company logo.

    Supports Fast Modbus ⚡, which allows you to instantly deliver the effective voltage value to the Wiren Board controller.

    Hardware

    Specifications:

    • 4 active outputs 0-20 mA or 4-20 mA.
    • Load resistance: up to 500 Ohm.
    • 4 discrete inputs.
    • Galvanic isolation of inputs.
    • Supply voltage: 9…28 V DC.
    • Interface: RS-485, Modbus RTU.
    • Extended operating temperature range: -40…+80 °C.
    • DIN rail housing, 3 modules.
    WB-MAO4-20mA Hardware

    Fast Modbus support

    All Wiren Board devices, in addition to the standard Modbus RTU, can work with its extension Fast Modbus ⚡, which adds new features:

    • instant polling of input states and measured values via events;
    • quick search for devices connected to the controller;
    • resolving address collisions on the bus.

    Additional features are enabled automatically - if the device supports extension, the controller driver will work with the device quickly Modbus if the device does not know anything about the extension - it will work using standard Modbus RTU.

    WB-MAO4-20mA Fast Modbus Support

    Quality control at each stage of production

    We develop and manufacture all Wiren Board devices ourselves. Also everyone devices undergo multi-stage quality control:

    • During development - checking the components used for compliance with the declared ones characteristics and testing of the prototype device at extreme operating conditions.
    • After installation of SMD components - automated optical control.
    • After soldering the lead components - visual inspection of soldering.
    • After assembling the device, functional testing on an automated stand.
    • When shipped to the warehouse - control of completeness, stickers, appearance.

    Thanks to this approach, the failure rate is no more than 0.5% of all released devices.

    If the device fails within two years from the date of purchase, we will replace it for free without need to be sent to a service center.

    Wiren Board Quality Control

    Settings

    When used with the Wiren Board controller, you can use the mouse in the web interface to:

    • set the operating range - 0-20 mA, 4-20 mA or custom,
    • set the minimum and maximum current values,
    • set the rate of change of current,
    • set up the processing of button presses on the inputs and the interaction of inputs with outputs,
    • enable and disable parameter polling.

    For configuration without a controller, you can use the Wiren Board Device Editor paired with a WB-USB485 interface converter or a similar device.

    When used with other equipment, the module can be configured via the RS-485 bus by writing values to Modbus registers. The register table is open, well documented and available online in the device documentation.

    WB-MAO4-20mA Settings

    Reading the readings

    The voltmeter does not have its own screen, so reading the connected parameters is carried out via the RS-485, Modbus RTU interface.

    If a Wiren Board controller is used, the measured values are available in the controller's web interface and can be transferred to the higher-level system. The device card displays only the channels enabled in the survey settings.

    All data can be read by any equipment or software that supports the RS-485, Modbus RTU protocol: third-party controllers, HMI panels or SCADA.

    WB-MAO4-20mA Reading the Readings
    BrandWiren Board
Close window